《電子技術應用》
您所在的位置:首頁 > 電源技術 > 解決方案 > ONSEMINCP125525W離線電流模式PWM控制器參考設計方案

ONSEMINCP125525W離線電流模式PWM控制器參考設計方案

2013-09-09

ONSEMI公司的NCP1255是一款soic-8封裝的堅固高性能離線高集成PWM控制器,輸入電壓范圍最高可達35V。該控制器具有過功率保護、掉電保護、輕載變頻、斜率補償、內建軟啟動、過載及短路自動定時恢復等功能。本文首先介紹芯片的簡介、特性、內部框圖及應用領域,并給出相應設計方案的設計原理圖、元器件列表及PCB元件布局圖。

The NCP1255 is a highly integrated PWM controller capable of delivering a rugged and high performance offline power supply in a SOIC−8 package. With a supply range up to 35 V, the controller hosts a jittered 65−kHz switching circuitry operated in peak current mode control. When the power on the secondary side starts to decrease, the controller automatically folds back its switching frequency down to a minimum level of 26 kHz. As the power further goes down, the part enters skip cycle while freezing the peak current setpoint.

To help build rugged converters, the controller features several key protective features: a brown−out, a non−dissipative Over Power Protection for a constant maximum output current regardless of the input voltage, two latched over voltage protection inputs – either through a dedicated pin or via the Vcc input − and finally, the possibility to externally adjust an auto−recovery timer duration.

The controller architecture is arranged to authorize a transient peak power excursion when the peak current hits the limit. At this point, the switching frequency is increased from 65 kHz to 130 kHz until the peak requirement disappears. The timer duration is then modulated as the converter crosses a peak power excursion mode (long) or undergoes a short circuit (short).

NCP1255主要特性:

• 65−kHz Fixed−frequency Current−mode Control Operation with 130−kHz Excursion
• Internal and Adjustable Over Power Protection (OPP) Circuit
• Adjustable Brown−Out Protection Circuit
• Frequency Foldback down to 26 kHz and Skip−cycle in Light Load Conditions
• Adjustable Slope Compensation
• Internally Fixed 4−ms Soft−start
• Adjustable Timer−based Auto−recovery Overload/Short−circuit Protection
• 100% to 25% Timer Reduction from Overload to Short−circuit Fault
• Double Vcc Hiccup for a Reduced Average Power in Fault Mode
• Frequency Jittering in Normal and Frequency Foldback Modes
• Latched OVP Input for Improved Robustness and Latched OVP on Vcc
• Up to 35−V Vcc Maximum Rating
• Extremely Low No−load Standby Power
• This is a Pb−Free Device

NCP1255應用:

• Converters requiring peak−power capability such as printers power supplies, ac−dc adapters for game stations.

 
圖1. NCP1255內部方框圖

NCP1255方案介紹:

The NCP1255 features several novelties compared to the NCP1250 previously released. The key feature of this component lies in its ability to push the switching frequency as the converter experiences a sudden power increase.However, this available extra power delivery can only be maintained for a certain amount of time. Beyond this duration, the controller gives up and enters an auto-recovery mode. This mode is perfectly suited for converters supplying highly variable loads such as Haswell-based notebook adapters or inkjet printers to cite a few possible examples.

General Description

The part is encapsulated in a SOIC−8 package but a reduced-feature set version (no brown-out and timers are internally set), the NCP1254, also exists in a tiny TSOP−6 package. Featuring a low-power BiCMOS process, the die accepts to work with VCC levels up to 35 V, safely clamping the drive voltage below 12 V. With its 15 _A start-up current, a high-value resistive network can be used in offline applications to crank the converter, naturally minimizing the wasted power in high-line conditions. In nominal load operations, the switching frequency of this peak-current mode control circuit is 65 kHz.

When the power demand goes up, the controller increases the peak current setpoint until it reaches the upper limit (0.8 V over Rsense, no opp). At this point, the output power demand increase can only be answered by further shifting the switching frequency up until it reaches another limit, 130 kHz. The maximum power is thus obtained at this moment. On the contrary, in light-load operations, the part linearly reduces its switching frequency down to 26 kHz and enters skip cycle as power goes further down. This mode of operation favors higher efficiency from high to moderate output levels and ensures the lowest acoustic noise in the transformer. To improve the EMI signature, a low-frequency modulation brings some dither to the switching pattern. Unlike other circuits, the dither is kept in foldback and peak excursion modes, continuously smoothing the noise signature.

The part hosts several new protection means such as an auto-recovery brown-out circuit. It is adjustable via a resistive divider. A double hiccup on the VCC brings down the average input power while in auto-recovery fault mode.

Board Description

The application schematic that appears in Figure 1 has been optimized to limit the leakage inductance losses and maximize the efficiency. For this purpose, the RDC clamping network has been replaced by a TVS-based circuitry, leaving enough swing to the 800 V MOSFET. Again, a 600 V type could have been used but would have hampered the drain voltage dynamics at turn off. A capacitor in parallel with the TVS limits its peak current at the switch opening and helps softening the radiated noise. Besides its excellent performance in standby, the TVS approach helps to maintain a safe clamping level given the wide output power excursion.

The chip supply is brought in via pin 6. Please note that the start-up resistances, besides cranking the controller, also perform the X2 discharge function for free. Upon start-up, for a voltage less than 18 V (typical), the internal consumption is limited to 15 _A maximum. It suddenly changes to a few mA as the controller starts to drive the 800 V MOSFET at 130 kHz when VCC reaches 18 V. The auxiliary voltage can go down to around 9 V before the controller safely stops the switching pulses. The first VCC capacitor C3 must be sized so that the auxiliary winding takes over before the UVLO is touched. The auxiliary winding is tailored to deliver an auxiliary voltage above 12 V and it drops to 10 V in no-load conditions. This guarantees a good no-load standby power performance as you will read below. A low-valued resistance (R13) limits the voltage excursion on this auxiliary voltage in short circuit situations.

Regulation is ensured by pulling down the dedicated pin via an optocoupler, driven from the secondary side by a NCP431. This new device does not require a 1 mA bias current as it was the case with the classical TL431. The absence of this bias current greatly contributes to reducing the no-load standby power.

NCP1255方案原理圖:

  

圖2. NCP1255方案原理圖

NCP1255方案材料清單:





PCB元件布局圖:


 


本站內容除特別聲明的原創文章之外,轉載內容只為傳遞更多信息,并不代表本網站贊同其觀點。轉載的所有的文章、圖片、音/視頻文件等資料的版權歸版權所有權人所有。本站采用的非本站原創文章及圖片等內容無法一一聯系確認版權者。如涉及作品內容、版權和其它問題,請及時通過電子郵件或電話通知我們,以便迅速采取適當措施,避免給雙方造成不必要的經濟損失。聯系電話:010-82306118;郵箱:[email protected]
主站蜘蛛池模板: 在线观看欧美亚洲日本专区 | 欧美精品在线视频观看 | 特黄aa级毛片免费视频播放 | 香港日本韩国三级网站 | 国产精品视频一区二区猎奇 | 久久精品免费一区二区视 | 久久久国产亚洲精品 | 韩国一级毛片大全女教师 | 国内国语一级毛片在线视频 | 欧美三级欧美成人高清www | 欧美激情精品久久久久 | 亚洲日本欧美产综合在线 | a级高清观看视频在线看 | 国产一区二区三区四区波多野结衣 | 91国语对白 | 久久99热精品免费观看k影院 | 久久久免费的精品 | 91久久国产成人免费观看资源 | 欧美久草视频 | 天堂色视频 | 久久国产精品二国产精品 | 久久久久久国产精品视频 | 成人禁在线观看网站 | 动漫精品一区二区 | 最新中文字幕一区二区乱码 | 国产偷国产偷亚洲高清在线 | 久久久国产精品网站 | 一区二区三区高清视频在线观看 | 国产成人亚洲毛片 | 波多野结衣在线播放视频 | 国产精品九九视频 | 日本二级毛片免费 | 精品视频在线播放 | 99视频福利| 看欧美的一级毛片 | 成人欧美网站 | 天天爱天天做天天爽天天躁 | 九草视频 | 国产丝袜美女一区二区三区 | 九九九九九九 | 亚洲国产精品网 |